All things Smart Terms Specific to Amia Sharesource Amia
100
Smart Drain
Smart Dwell
Smart Therapy
Name the 3 smart features of the Amia
100
the primary program is the program that you will use most often. it is loaded as the default program
Primary Program
100
30 days
After how many days of not logging into Sharesource will you need your password reset?
100
The drain exceeds the MPV by at least 15%
Excessive Drain Deviation means
100
10

How many characters are available for Program Name
200
Automatically adjust the dwell times up or down to complete the treatment in the prescribed therapy time
What is Smart Dwell
200
a therapy that requires the clinician to program the therapy time, night therapy volume and fill volume
Time-Bases Method
200
4
How many treatments can you program into Sharesource
200
PD 4 low Calcium 1.25 mmol/L
PD 101 high Calcium 1.75 mmol/L
What is the Difference between
PD 101 and PD 4
200
Cord
Modem
When a patient has to swap out their cycler what do they need to keep?
300
Smart therapy is a tidal therapy that uses most of the available solution. Does this by adding 1 or 2 extra cycles to the treatment
What is Smart Therapy
300
a therapy that requires the clinician to program the cycle fill volume, dwell time and number of cycles
Cycle based Method
300
No
Can you log into Sharesource at any time and see how a patients treatment is going>
300
Your UF is significantly more or less than expected for the night portion of therapy
Expected UF Deviation means
300
Yes
Is a new patient consent required when ever a patient has to swap out their cycler?
400
Smart drain is a treatment option that allows you to continue treatment when experiencing drain problems during the night portion of therapy .
What is Smart Drain
400
When the patient connects to the Amia cycler during the day to complete a exchange.
Day Cycles
400
Not true only issues you have chosen as a alert will be flagged
Any issues during treatment will be flagged on the Sharesource dashboard
400
You drained significantly more or less than expected in the initial drain.
(min initial drain setting-the actual drain)is not withing =/- 50% of night fill volume per cycler
Initial Drain Deviation means
400
Amia Care is a Baxter service which provides proactive maintenance to the Amia system to lessen the likelihood that a patient will experience a therapy interruption. Preventive maintenance is performed while the equipment is still working to keep it running smoothly
What is Amia Care??
500
Smart Drain Limit Volume is the MPV allowed to remain tin the peritoneal cavity prior to moving on to the next fill phase
What is the Smart Drain Limit Volume
500
the amount of fluid the system has calculated to be in the peritoneal cavity during you APD night therapy.
Estimated Peritoneal Volume
500
True
Baxter needs that patients Date of birth for the patient to be activated in Sharesource
500
Lost total therapy volume is greater than 5%
Lost dwell time Deviation means
500
Date and Time
What do you or your patient need to check whenever you are using a new Amia cycler






Amia and Sharesource