IBC Basics | BOMA | ADA/TAS | Code Calculations | Free for All |
---|---|---|---|---|
What is 20 feet
The distance allowed for a dead end corridor in a non-sprinklered building
|
What is Major Vertical Penetrations
Exit Stairs and Elevators are examples of...
|
What is 60 inches
Turn around space required
|
What is 90 feet
Exit separation where the longest diagonal of an unsprinklered suite is 180 feet
|
What is Assembly and 15 square feet/person
Occupancy Type and load factor of a Conference Center
|
What is 150 square feet/person
The occupant load for Business Occupancy in IBC 2018
|
What is Building Service Area
With BOMA 2017 the lowest accessible level of a vertical penetration
|
What is 1'-6"
Clearance required at pull side of door when closer is present
|
What is 51
occupancy of a an office space with USF of 7546 according to IBC 2018
|
What is 32 inches
Minimum clear width of a Door
|
What is the Point of Decision
That portion of exit access which the occupants are required to traverse before two separate and distinct paths of egress travel to two exits are available
|
What is Building Owners and Managers Associations
BOMA an acronym that stands for...
|
What is 30" and 27"
Minimum width and height at knee clearance
|
What is 176
occupancy of an office space with USF of 12,369 with a conference room that is1540 sf and a break room is 900 sf according to IBC 2018
|
What is Building Service Area
BOMA classification of a building lobby
|
What is exit separation
Shall not be less than 1/3 the length of the longest diagonal when equipped with a sprinkler system
|
What inside of the wall on the Building Circulation Side/Floor Service Area gets the wall
Location of line when floor service area meets base building circulation
|
What is 48 inches maximum and 15 inches minimum
A forward unobstructed reach range
|
What is 10
1 per 25 for first 50 and 1 per 50 for remaining exceeding 50
Number of Water closets required for Business occupancy load of 450 people
|
What is the Exit Access, Exit, and Exit Discharge
The 3 parts of an Exit Route
|
What is any point along the width of the doorway
Where measurements on exits/exit access doors is taken
|
What is Method B
Determines Rentable Area by proportionately allocating shared Service and Amenity Areas along with Base Building Circulation to Building Occupants using a Single Load Factor
|
What is 1-1/4" minimum and 2" maximum
Circular Grab Bar Cross Sectional outside diameter range
|
What is 320 people.
standard clear width is 32" divide that by .2 and double it because you have 2 doors.
Exit capacity for a non sprinklered Business Occupancy floor with 2 standard Exit doors
|
What is 28