IBC Basics BOMA ADA/TAS Code Calculations Free for All
100
What is 20 feet
The distance allowed for a dead end corridor in a non-sprinklered building
100
What is Major Vertical Penetrations
Exit Stairs and Elevators are examples of...
100
What is 60 inches
Turn around space required
100
What is 90 feet
Exit separation where the longest diagonal of an unsprinklered suite is 180 feet
100
What is Assembly and 15 square feet/person
Occupancy Type and load factor of a Conference Center
200
What is 150 square feet/person
The occupant load for Business Occupancy in IBC 2018
200
What is Building Service Area
With BOMA 2017 the lowest accessible level of a vertical penetration
200
What is 1'-6"
Clearance required at pull side of door when closer is present
200
What is 51
occupancy of a an office space with USF of 7546 according to IBC 2018
200
What is 32 inches
Minimum clear width of a Door
300
What is the Point of Decision
That portion of exit access which the occupants are required to traverse before two separate and distinct paths of egress travel to two exits are available
300
What is Building Owners and Managers Associations
BOMA an acronym that stands for...
300
What is 30" and 27"
Minimum width and height at knee clearance
300
What is 176
occupancy of an office space with USF of 12,369 with a conference room that is1540 sf and a break room is 900 sf according to IBC 2018
300
What is Building Service Area
BOMA classification of a building lobby
400
What is exit separation
Shall not be less than 1/3 the length of the longest diagonal when equipped with a sprinkler system
400
What inside of the wall on the Building Circulation Side/Floor Service Area gets the wall
Location of line when floor service area meets base building circulation
400
What is 48 inches maximum and 15 inches minimum
A forward unobstructed reach range
400
What is 10

1 per 25 for first 50 and 1 per 50 for remaining exceeding 50
Number of Water closets required for Business occupancy load of 450 people
400
What is the Exit Access, Exit, and Exit Discharge
The 3 parts of an Exit Route
500
What is any point along the width of the doorway
Where measurements on exits/exit access doors is taken
500
What is Method B
Determines Rentable Area by proportionately allocating shared Service and Amenity Areas along with Base Building Circulation to Building Occupants using a Single Load Factor
500
What is 1-1/4" minimum and 2" maximum
Circular Grab Bar Cross Sectional outside diameter range
500
What is 320 people.

standard clear width is 32" divide that by .2 and double it because you have 2 doors.
Exit capacity for a non sprinklered Business Occupancy floor with 2 standard Exit doors
500
What is 28
How many locations does DLR Group have offices in